S-60

S Series / S-60
SWITCHING POWER SUPPLY

S-60

60W Single Output Switching Power Supply

Compact enclosed AC/DC switching power supply available in 5V, 12V, 15V and 24V output versions for industrial control equipment, automation applications, electronic equipment and general power supply use.

Hong Kong MING WELL S-60 switching power supply
60W Rated Power
5–24V Output Voltage Options
85–264VAC AC Input Range
Up to 79% Efficiency
159 × 97 × 38 mm Overall Dimensions

S-60 Switching Power Supply

The S-60 Series provides four single-output DC versions: 5V, 12V, 15V and 24V, with 60W rated output power.

The S-60 is an enclosed AC/DC switching power supply designed for stable DC power delivery in industrial control equipment, electronic systems and general power supply applications.

The series provides universal 85–264VAC input, free-air convection cooling, overload and overvoltage protection, 100% full-load burn-in testing and a fixed 77KHz switching frequency.

Universal AC Input

Wide 85–264VAC input range with 120–370VDC input support.

Four Output Versions

Available in 5V, 12V, 15V and 24V DC output models.

Compact Enclosed Design

159 × 97 × 38 mm enclosed design with free-air convection cooling.

Protection Functions

Built-in overload and overvoltage protection with automatic recovery.

S-60 Model Range

Electrical output specifications for each available voltage version.

Swipe horizontally to view all models →
Specification S-60-5 S-60-12 S-60-15 S-60-24
DC Voltage 5V 12V 15V 24V
Rated Current 12A 5A 4A 2.5A
Current Range 0–12A 0–5A 0–4A 0–2.5A
Rated Power 60W 60W 60W 60W
Ripple & Noise 120mVp-p 120mVp-p 150mVp-p 150mVp-p
Voltage Adjustment Range 4.75–5.5V 10.8–13.2V 13.5–16.5V 21.6–26.4V
Voltage Tolerance ±2% ±1% ±1% ±1%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±0.5% ±0.5% ±0.5%
Efficiency 73% 76% 77% 79%
Overvoltage Protection 5.75–6.75V 13.8–16.2V 17.25–20.25V 27.6–32.4V

General Specifications

Input

Voltage Range 85–264VAC;
120–370VDC
Frequency Range 47–63Hz
AC Current 2A / 115VAC;
1A / 230VAC
Inrush Current 20A / 115VAC;
40A / 230VAC, cold start
Leakage Current < 3.5mA / 240VAC

Timing

Setup / Rise Time 300ms / 50ms at 230VAC;
800ms / 50ms at 115VAC,
at full load
Hold-up Time 80ms typ. at 230VAC;
12ms typ. at 115VAC,
at full load

Environment

Working Temperature -10°C to +60°C
(refer to output load derating curve)
Working Humidity 20–90% RH, non-condensing
Storage Temperature / Humidity -20°C to +85°C;
10–95% RH
Temperature Coefficient ±0.03% / °C (0–50°C)
Vibration 10–500Hz, 2G, 10 min/cycle;
60 min each along X, Y and Z axes

Safety & Mechanical

Withstand Voltage I/P–O/P: 3KVAC;
I/P–FG: 2KVAC;
O/P–FG: 0.5KVAC
Isolation Resistance I/P–O/P, I/P–FG, O/P–FG:
100MΩ / 500VDC / 25°C / 70%RH
MTBF ≥ 316.2K hrs,
MIL-HDBK-217F (25°C)
Dimensions 159 × 97 × 38 mm
Weight / Packaging 0.51kg;
24pcs / 13.1kg / 0.7CUFT

Safety Standards

Safety Norms UL1012;
UL60950-1;
TUV EN60950-1

Design Features

Cooling Cooling by free air convection
Burn-in Test 100% full-load burn-in test
Switching Frequency Fixed 77KHz
Input Design Universal AC input / full range

Built-in Protection Functions

Overload Protection

Protection operates at approximately 105%–150% of rated output power. Hiccup mode protection is used, and the power supply automatically recovers after the fault condition is removed.

Overvoltage Protection

Overvoltage protection levels are 5.75–6.75V for S-60-5, 13.8–16.2V for S-60-12, 17.25–20.25V for S-60-15 and 27.6–32.4V for S-60-24.

Short Circuit Protection

Short-circuit conditions are handled by the built-in hiccup protection function. Normal operation automatically resumes after the fault condition is removed.

S-60 Dimension Drawing

Outline dimensions and mounting dimensions.

S-60 switching power supply dimension drawing
Overall Size: 159 × 97 × 38 mm
DIMENSIONS IN MILLIMETERS