DR-30

DR / DRP Series / DR-30
DIN RAIL SWITCHING POWER SUPPLY

DR-30

15–35W DIN Rail Switching Power Supply

Compact DIN rail AC/DC switching power supply available with 5V, 12V, 15V and 24V DC output versions for control equipment, automation systems and electrical cabinet applications.

DR-30 DIN rail switching power supply
15–35W Rated Power Range
5–24V Output Voltage Options
85–264VAC AC Input Range
Up to 80% Efficiency
78 × 93 × 56 mm Overall Dimensions
PRODUCT OVERVIEW

DR-30 DIN Rail Power Supply

The DR-30 Series provides four DC output voltage versions: 5V, 12V, 15V and 24V. Rated output power ranges from 15W to 35W depending on the selected model.

Universal AC Input

85–264VAC or 120–370VDC input range.

Four Output Versions

5V, 12V, 15V and 24V DC output options.

Compact DIN Rail Design

Compact enclosure for DIN rail control cabinet installation.

Built-in EMI Filter

Built-in EMI filter for reduced ripple and interference.

OUTPUT SPECIFICATIONS

DR-30 Model Range

Electrical output specifications for each available voltage version.

Specification DR-30-5 DR-30-12 DR-30-15 DR-30-24
DC Voltage 5V 12V 15V 24V
Output Voltage Tolerance ±2% ±1% ±1% ±1%
Rated Current 3A 2A 2A 1.5A
Current Range 0–3A 0–2A 0–2A 0–1.5A
Ripple & Noise 100mVp-p 200mVp-p 240mVp-p 480mVp-p
Line Regulation ±1% ±1% ±1% ±1%
Load Regulation ±1% ±1% ±1% ±1%
Rated Power 15W 24W 30W 35W
Efficiency 72% 77% 77% 80%
Voltage Adjustment Range 4.75–5.5V 10.8–13.2V 13.8–16.5V 21.6–26.4V
TECHNICAL DATA

General Specifications

Input

Voltage Range 85–264VAC / 120–370VDC
Frequency Range 47–63Hz
AC Current 1.5A / 115VAC, 0.75A / 230VAC
Inrush Current 30A / 115VAC, 60A / 230VAC, cold start
Leakage Current < 1mA / 240VAC

Timing

Start / Rise / Hold Time 800ms / 60ms / 50ms at 230VAC

Environment

Working Temperature / Humidity -10°C to +50°C, 20–90% RH
Storage Temperature / Humidity -20°C to +85°C, 10–95% RH
Temperature Coefficient ±0.03% / °C (0–50°C), on +5V output
Vibration 10–500Hz, 2G, 10 min/cycle; X, Y and Z axes, 60 min each

Safety & Mechanical

Withstand Voltage I/P–O/P: 1.5KVAC;
I/P–FG: 1.5KVAC;
O/P–FG: 0.5KVAC
Isolation Resistance I/P–O/P, I/P–FG, O/P–FG: 100MΩ / 500VDC
Dimensions 78 × 93 × 56 mm
Weight 0.27kg

Safety Standards

Safety Norms Meets the requirements of UL1012 (do not apply for marking)

Design Features

Cooling Natural convection cooling
Construction Compact size and lightweight design
EMI Filter Built-in EMI filter
Burn-in Test 100% full-load burn-in test
PROTECTION

Built-in Protection Functions

Overload Protection

Protection operates at approximately 105%–150% of rated output power. The output is cut off when protection is activated and automatically recovers after the abnormal condition is removed.

Short Circuit Protection

Built-in short-circuit protection helps protect the power supply and connected equipment under abnormal output conditions.

MECHANICAL DIMENSIONS

DR-30 Dimension Drawing

DIN rail enclosure and mounting dimensions.

DR-30 mechanical dimension drawing
Overall Size: 78 × 93 × 56 mm
DIMENSIONS IN MILLIMETERS
APPLICATIONS

Typical Applications

Control Equipment Low-power industrial and electronic control equipment.
Control Cabinets DIN rail installations in electrical control panels.
Automation Systems Compact DC power for automation equipment.
Electronic Equipment 5V, 12V, 15V and 24V DC powered equipment.

Need a Quote for DR-30?

Tell us the required output voltage, quantity and application. Our team will assist with DR-30 model selection and quotation.

Request A Quote →