EDR-75
Slim industrial DIN rail AC/DC switching power supply available with 12V, 24V and 48V DC output versions for industrial control, automation, electrical cabinets and DIN rail equipment.
EDR-75 DIN Rail Power Supply
The EDR-75 Series provides three DC output versions: 12V, 24V and 48V. Rated output power ranges from 75.6W to 76.8W depending on the selected model.
Wide AC Input
90–264VAC or 127–370VDC input range.
Three Output Versions
12V, 24V and 48V DC output options.
Slim DIN Rail Design
32 mm wide enclosure for space-conscious DIN rail installations.
High Efficiency
Efficiency reaches up to 88.5% depending on the selected output model.
EDR-75 Model Range
Electrical output specifications for each available voltage version.
| Specification | EDR-75-12 | EDR-75-24 | EDR-75-48 |
|---|---|---|---|
| DC Voltage | 12V | 24V | 48V |
| Rated Current | 6.3A | 3.2A | 1.6A |
| Current Range | 0–6.3A | 0–3.2A | 0–1.6A |
| Rated Power | 75.6W | 76.8W | 76.8W |
| Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p |
| Voltage Adjustment Range | 12–14V | 24–28V | 48–55V |
| Voltage Accuracy | ±2.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±1.0% | ±1.0% | ±1.0% |
| Efficiency | 85.5% | 87.5% | 88.5% |
| Overvoltage Protection | 14–17V | 29–33V | 56–65V |
General Specifications
Input
Timing
Environment
Safety & Mechanical
Safety Standards
TUV EN60950-1;
EN60335-1;
EN61558-1/-2-16;
CCC GB4943.1;
BSMI CNS14336-1;
EAC TC TP 004;
AS/NZS 60950.1 (by CB)
EMC
EN61000-3-2;
EN61000-3-3
EN55024;
EN61000-6-2 (EN50082-2);
Class A heavy industrial environment
Built-in Protection Functions
Overload Protection
Protection operates at approximately 105%–130% of rated output power. Constant current limiting protection is used and the power supply automatically recovers after the abnormal load condition is removed.
Overvoltage Protection
Overvoltage protection turns off the output voltage. Protection levels are 14–17V for the 12V model, 29–33V for the 24V model and 56–65V for the 48V model. Recovery is achieved after restarting the power supply.
Over Temperature Protection
The output is shut down when the over-temperature protection is activated. Recovery is achieved after restarting the power supply.
EDR-75 Dimension Drawing
Slim industrial DIN rail enclosure and mounting dimensions.
Typical Applications
Need a Quote for EDR-75?
Tell us the required output voltage, quantity and application. Our team will assist with EDR-75 model selection and quotation.